It sounds like you’re encountering the classic smartctl error when trying to access a physical disk behind a Dell PERC (MegaRAID) controller. The message you're referencing is essentially telling you to use the correct device syntax: -d megaraid,N.
Note: On some systems, you may need to use /dev/bus/0 instead of /dev/sda to ensure stability. Recommended Monitoring Configuration It sounds like you’re encountering the classic smartctl
NIf you try -d megaraid,999 on a system with only 4 drives, smartctl will fail similarly. Always verify the correct IDs with storcli or by trial with small range. Use perccli/storcli to list drives and feed physical
Check SMART status for physical drive 0: Check SMART status for physical drive 0:
-a : Display all S.M.A.R.T. information (or use -i for identity, -H for health, -A for attributes)-d megaraid,N : Disk type and physical drive number/dev/sda : The logical device corresponding to the RAID array containing that physical disk