Fire Prevention And Extinction Rules 2014 Bangladesh Pdf __exclusive__
The Fire Prevention and Extinction Rules, 2014 (অগ্নি প্রতিরোধ ও নির্বাপণ বিধিমালা, ২০১৪) is a set of regulations issued by the Bangladesh government to implement the Fire Prevention and Firefighting Act, 2003. These rules provide the technical and administrative framework for fire safety, licensing, and building compliance across the country. Key Regulatory Elements
- Fines (up to BDT 50,000) and/or imprisonment (up to 6 months) for violations.
- Closure orders for continued non-compliance.
4.2. Responsibilities of Building Owners
The rules place the "duty of care" squarely on the building owner or occupier. Key responsibilities include: fire prevention and extinction rules 2014 bangladesh pdf
4. Building Design and Access Requirements
- Emergency exits: Minimum width 1.0 m (0.9 m for small residential); must open outward; signage with glow-in-the-dark tape; no locking from inside without panic bars.
- Staircases: At least two separate, enclosed, fire-rated staircases for buildings > 3 floors; no storage or gas cylinders in stairs.
- Fire vehicle access: Bridge-free, obstruction-free road of minimum 4.5 m width leading to the building; turning radius for fire trucks; fire hydrants within 60 m of building entrance.
- Basement restrictions: No basement used for storage of LPG, petrol, or highly flammable liquids unless specifically approved with explosion relief vents.