Cem Dual Mig 120 Manual ((exclusive)) May 2026
CEM Dual MIG 120 Manual
4.4. Gas Connection (for MIG/MAG)
- Use CO₂ or Ar/CO₂ mix (e.g., 75/25).
- Regulator connects to cylinder, gas hose to machine rear.
- Set flow rate: 8–12 L/min.
- Turn gas on at cylinder before welding.
- Revision 1.0: Initial release
WARNING: Read entire manual before use. Welding produces intense UV light, heat, sparks, and fumes. cem dual mig 120 manual
If you’ve just inherited one of these Italian-made workhorses or picked it up at an estate sale, here is the essential "manual" and guide to getting it running. 1. Identifying Your Machine CEM Dual MIG 120 Manual 4
Polarity: For Gas (Solid Wire), the torch is usually Positive (+). For Gasless (Flux-Cored), the torch is usually Negative (-). Check the internal terminals near the wire feed motor to switch these. 4. Maintenance Tips Use CO₂ or Ar/CO₂ mix (e
- Input Voltage: 230V, 50Hz
- Power Consumption: 6.5 kW
- Welding Current Range: 30-120A
- Welding Voltage Range: 10-20V
- Wire Feed Speed: 1.5-15m/min
- Duty Cycle: 60% at 100A, 30% at 120A
- Weight: 45kg
- Dimensions: 550x350x450mm